Checked against the law on 12 November 2026.
Do I need planning permission for an air source heat pump?
In England, an air source heat pump on a house is likely permitted development if it meets the MCS noise standard, the outdoor unit (with any housing) is no more than 1.5 cubic metres, and it is not on a pitched roof. There can be one heat pump on a house, or two on a detached house. A heat pump on land, or on a building in the grounds, of a listed house is not permitted development, and on the listed house itself the checker asks the council. It is not permitted on a scheduled monument. In a conservation area or World Heritage Site, it cannot be on a wall or roof that fronts a highway. Outside those areas, a unit on a wall of the house that fronts a highway above the ground floor is not permitted. Otherwise it likely needs planning permission.
Check your address
The address matters because listed buildings, conservation areas, World Heritage Sites, Article 4 directions and planning conditions can take this right away or tighten it.
The rules
- Microgeneration only. The right covers a microgeneration heat pump. For heat, that means a capacity of no more than 45 kilowatts thermal. Schedule 2, Part 14, Class G, paragraph G (microgeneration), with section 82(6) of the Energy Act 2004
- Noise. The heat pump must comply with the MCS Planning Standards, which are MCS 020 a), the sound calculation for permitted development installations. Schedule 2, Part 14, Class G, paragraph G.1 (and paragraph P, MCS Planning Standards)
- How many. There can be no more than one air source heat pump on a house that is not detached, or two on a detached house (one that shares no party wall with a neighbouring building). A block of flats can have one. Schedule 2, Part 14, Class G, paragraph G.2(a)Schedule 2, Part 14, Class G, paragraph G.2(a)
- Size. The outdoor compressor unit, including any housing, can be no more than 1.5 cubic metres for a house, or 0.6 cubic metres for a block of flats. Schedule 2, Part 14, Class G, paragraph G.2(d)(i)Schedule 2, Part 14, Class G, paragraph G.2(d)(ii)
- Wind turbines. It is not permitted if a wind turbine is installed on the same building or in the grounds. Schedule 2, Part 14, Class G, paragraph G.2(b)Schedule 2, Part 14, Class G, paragraph G.2(c)
- Roofs. It cannot go on a pitched roof. On a flat roof it cannot be within 1 metre of the outer edge of the roof. Schedule 2, Part 14, Class G, paragraph G.2(f)Schedule 2, Part 14, Class G, paragraph G.2(g)
- Walls facing the road. Outside a conservation area or World Heritage Site, it cannot go on a wall that fronts a highway above the ground floor storey. Schedule 2, Part 14, Class G, paragraph G.2(k)
Worked examples
- A single heat pump unit of 1 cubic metre on the side of a detached house, passing the MCS noise calculation: within the limits, so it is likely permitted development.
- A unit of 1.6 cubic metres: over the 1.5 cubic metre limit for a house, so it likely needs planning permission.
- A heat pump on a pitched roof: not permitted under Class G, so it likely needs planning permission.
Designated land and listed buildings
A heat pump on land, or on a building in the grounds, of a listed house is not permitted development, and neither is one on a scheduled monument. On the listed house itself, the wording is unclear, so ask the council. Schedule 2, Part 14, Class G, paragraph G.2(i)Schedule 2, Part 14, Class G, paragraph G.2(i)Schedule 2, Part 14, Class G, paragraph G.2(h)
In a conservation area or World Heritage Site, it cannot go on a wall or roof that fronts a highway. It also cannot be nearer to a highway bounding the property than the nearest part of the house. Schedule 2, Part 14, Class G, paragraph G.2(j)(i)Schedule 2, Part 14, Class G, paragraph G.2(j)(i)Schedule 2, Part 14, Class G, paragraph G.2(j)(ii)Schedule 2, Part 14, Class G, paragraph G.2(j)(ii)
Conditions
- It must not be used only for cooling. Schedule 2, Part 14, Class G, paragraph G.3(aa)
- It must, so far as practicable, be sited to minimise its effect on the look of the building and the amenity of the area. Schedule 2, Part 14, Class G, paragraphs G.3(b), (c)
- It must be removed as soon as reasonably practicable when no longer needed. Schedule 2, Part 14, Class G, paragraph G.3(d)
- A condition on the house's planning permission, or an Article 4 direction, can remove the right. Article 3(4)Article 4(1)
What this checker cannot see
It cannot see the result of your MCS noise calculation, the exact size of the unit, or any listed building consent. Building regulations and your installer's certification are separate.
What to do next
Enter your postcode above to see the constraints at your address. To get the council's written confirmation, apply for a lawful development certificate . We are preparing a paid report for your address, with the constraints, the limits for your project, the sources and the questions to ask the council.
Change log
- : First published.
Last updated 12 November 2026.